header top curve
Home   >   Industries   >   Flat Panel Display   >   Facilities for Flat Panel Display Applications   >   QuickChange® Filters   >   QuickChange® AT Cartridge Filters

Industries

Select one or more of the following fields in order to begin your search.
  Search by Industry   Applications or process step   Keyword or Product Name      
   and/or   and/or      Search

Special Note: Some product links may direct you to our peripheral websites (devicecare.com, diskcare.com, entegrisfluidhandling.com, wafercare.com, entegris-services.com, or entegrisfuelcells.com)

QuickChange AT Filters

Nondewetting membrane technology in a prewet filter that delivers rapid changeout and improved operating efficiency
 
  • Nondewetting PTFE membrane filter, prewet and packaged in ultrapure DI water
  • Unique patented membrane prevents dewetting in air, during installation or chemical dumps/drains, and outgassing chemistries
  • Designed for use in any aqueous-based chemical
 
QuickChange AT Disposable Filters
Materials:Membrane: Patented nondewetting PTFE
Supports: PFA pleat supports
Disposable shell: PFA, containing ultrapure DI water
Membrane area:10”: 9000 cm2 (9.7 ft2 )
Connections:See ordering information.
Maximum operating conditions:Maximum forward differential pressure: 0.579 MPa (5.79 bar; 84 PSI) at 25°C; 0.0517 MPa (0.517 bar; 7.5 PSI) at 150°C
Maximum reverse differential pressure: 0.34 MPa (3.4 bar, 50 PSID) at 25°C
Maximum operating temperature: 150°C (302°F) at 0.5 bar (7.25 PSI)
QuickChange AT Cartridge Filter
Patented non-dewetting PTFE packaged in high purity DI water
Supports:PFA pleat supports, sleeve and endcaps
O-rings available:Viton® encapsulated with Teflon® fluoropolymer resin (TEV), Chemraz® elastomer, or Kalrez® perfluroelastomer
Membrane Area:9,000 cm2 (9.7 ft.2)
Connections:Code 0 (2-222) O-rings
Maximum Operating Conditions:Maximum Reverse Differential Pressure: 0.34 MPa (3.4 bar, 50 psid) @ 25° C
Maximum Forward Differential Pressure: 0.51 MPa (5.1 bar, 75 psid) @ 25° C
Maximum Forward Differential Pressure: 0.0517 MPa (0.517 bar, 7.5 psid) @ 150° C
Maximum Operating Temperature: 150° C at 0.5 bar (7.5 psi)
Cleanliness:< 25 particles/L > 0.5 μm after 17-minute water flush at 12 L/min.
TOC Recovery :TOC recovery within 10 ppb of feed after a 120-liter water flush at 1 L/min.
Resistivity Recovery:Resistivity recovery within 0.5 mega-ohm of feed after a 120-liter water flush at 1 L/min.