Aeronex SK Series Gas Purification System

Continuous ultrapure NH3 gas at a low cost of ownership
 
  • Removes gaseous contaminants such as H2O, CO2, and O2, to sub-ppb levels in ammonia gas
  • Self-regenerating purifiers provide the lowest cost of ownership and eliminates environmental concerns
  • Complete automatic operation saves time, increases reliability
  • System runs at ambient temperature and is field retrofittable into existing lines with low pressure drop
  • Systems rated for up to 120 SLM, or 300 SLM pure gas flow
 
Aeronex SK Series Gas Purification System
Gases purified:
NH3
Media type:
Inorganic
Contaminants removed:
H2O, CO2 and O2
Outlet purity:
<1 part-per-billion (ppb)
Operating pressure range:
515–1825 kPa (60–250 PSIG)
Pressure drop:
<15 PSI at 120 PSIG inlet and max rated flow
Maximum flow rate:
120 SLM, or 300 SLM
Gas operating temperature:
-40°C to +60°C (-40°F to +150°F)
Outlet filtration:
0.003 micron @ 99.9999999% efficiency
Leak rating:
1 × 10-9 atm cc/sec.