Aeronex® Z Series Gas Purification System

Continuous ultrapure XCDA® purge gas at a low cost of ownership
Data Sheet (1342104)
 
  • Removes gaseous contaminants such as SO2, SOX, NOX, H2S, H2O, CO2, siloxanes, ammonia, amines, acid gasses, alcohols and non-methane hydrocarbons to sub-ppb levels in CDA (air) gas
  • Self-regenerating purifiers provide the lowest cost of ownership and eliminates environmental concerns
  • Complete automatic operation saves time, increases reliability
  • System runs at ambient temperature and is field retrofittable into existing lines with low pressure drop
  • Removes contaminants to sub-ppb (part-per-billion) and ppt (part-per-trillion) levels
  • Systems rated for up to 120 SLM, 500 SLM or 1000 SLM pure gas flow
 
Aeronex® Z Series Gas Purification System
Gases purified:
CDA (air)
Media type:
Inorganic
Contaminants removed:
Volatile acids, volatile bases, refractory compounds, condensable organics, moisture
Outlet purity:
<1 part-per-billion (ppb)*
Operating pressure range:
515–1825 kPa (60–250 PSIG)

515–1136 kPa (60–150 PSIG)
Pressure drop:
<10 PSI at 120 PSIG inlet and max rated flow

EGPS12: <17 PSI at 90 PSIG and max rated flow
Maximum flow rate:
120 SLM, 500 SLM, or 1000 SLM
Gas operating temperature:
-40°C to +60°C (-40°F to +150°F)
Outlet filtration:
0.003 micron at 99.9999999% efficiency
Leak rating:
1 × 10-9 atm cc/sec.
Notes:
*Outlet purity is significantly lower for some contaminants. Test data available upon request.