QuickChange ATX Filters

Higher membrane area nondewetting PTFE membrane filter for aqueous chemistries
 
  • Nondewetting PTFE membrane filter, prewet and packaged in ultrapure DI water
  • Unique patented membrane prevents dewetting in air, during installation or chemical dumps/drains and outgassing chemistries
  • Designed for use in any aqueous-based chemical
  • Available in 4” and 10” cartridge with high membrane area available in 4” and 10” cartridge with high membrane area
 
QuickChange ATX Cartridge Filters
Materials:Membrane: Patented nondewetting PTFE packaged in ultrapure DI water
Supports: PFA pleat supports, sleeve and end caps
O-rings: See ordering information
Membrane area:ATX 4”: 5000 cm2 (5.4 ft2)
ATX 10”: 13000 cm2 (14.0 ft2)
Connections:Code 0 (2-222)
Maximum operating conditions:Maximum forward differential pressure: 0.45 MPa (4.5 bar, 65 PSID) at 25°C; 0.0517 MPa (0.517 bar, 7.5 PSID) at 150°C
Maximum reverse differential pressure: 0.34 MPa (3.4 bar, 50 PSID) at 25°C
Maximum operating temperature: 150°C (302°F) at 0.5 bar (7.5 PSI)
Cleanliness:<25 particles/L >0.5 μm after 17-minute water flush at 12 L/min.
TOC recovery:TOC recovery within 10 ppb (part-per-billion) of feed after a 120-liter water flush at 1 L/min.
Resistivity recovery within 0.5 mega-ohm of feed after a 120-liter water flush at 1 L/min.
QuickChange ATX Disposable Filters
Materials:Membrane: Patented nondewetting PTFE
Supports: PFA pleat supports
Disposable shell: PFA, containing ultrapure DI water
Membrane area:4”: 5000 cm2 (5.4 ft2)
10”: 13000 cm2 (14.0 ft2)
Connections:See ordering information.
Maximum operating conditions:Maximum forward differential pressure: 0.579 MPa (5.79 bar; 84 PSID) at 25°C; 0.0517 MPa (0.517 bar; 7.5 PSID) at 150°C
Maximum reverse differential pressure: 0.34 MPa (3.4 bar, 50 PSID) at 25°C
Maximum operating temperature: 150°C (302°F) at 0.5 bar (7.25 PSI)