Close
 
header top curve
Home   >   Industries   >   Semiconductor   >   Wet Etch and Clean   >   QuickChange® Filters   >   QuickChange® ATE Filter

Industries

Select one or more of the following fields in order to begin your search.
  Search by Industry   Applications or process step   Keyword or Product Name      
   and/or   and/or      Search

Special Note: Some product links may direct you to our peripheral websites (devicecare.com, diskcare.com, entegrisfluidhandling.com, wafercare.com, entegris-services.com, or entegrisfuelcells.com)

QuickChange® ATE Filters

Most advanced, best value filtration with the highest flow, especially for viscous chemistries
 
  • Available in retention ratings of 0.03 µm, 0.05 µm and 0.1 µm
  • 10 and 20" cartridge and Chem-Line® I and II disposable filter designs
  • Highest membrane surface area: 2.2 m² (23.7 ft²) PTFE membrane area - 10", 4.4 m² (47.4 ft²) - 20"
  • Utilizing advanced M-Pleating membrane technology for highest flow potential
 
QuickChange® ATE Filters
Materials:
Membrane: Prewet, nondewetting PTFE

Supports: PFA

Cartridge o-rings: TEV (Teflon® Encapsulated Viton®), Chemraz® or Kalrez®, Viton® Extreme™ EIP

Shell (for disposables): PFA (Chem-Line™ I and Chem-Line II type)
Retention ratings:
0.03 µm, 0.05 µm, 0.1 µm and 0.2 µm
Membrane area:
4" - N/A

10" - 2.2 m2 (23.7 ft2)

20" - 4.4 m2 (47.4 ft2)

30" - N/A
Cartridge connections:
Code 0 (2-222) o-rings
Maximum operating conditions:
Maximum forward differential pressure: 0.44 MPa (4.41 bar, 64 PSID) @ 25°C

Maximum forward differential pressure: 0.44 MPa (4.41 bar, 64 PSID) @ 25°C

Maximum reverse differential pressure: 0.35 MPa (3.5 bar, 50 PSID) @ 25°C

Maximum operating temperature: 180°C at 0.05 MPa (0.5 bar 7.3 PSI)
Metallic extractables:
Cartridge: Standard - <25 µg/device; UCM - <10 µg/device

Disposables: Standard - <10 µg/device; UCM - <3 µg/device
Particle shedding cleanliness:
<15 particles/10 mL > 0.2 µm at 5 L/min DI water flow
TOC recovery (per 10" equivalent):
Cartridges: within 10 ppb of feed after 120 L flush at 1 L/min

Disposables: within 5 ppb of feed after 25 minutes flush at 5 L/min
Resistivity recovery:
Resistivity recovery within 0.5 mega-ohm of feed after a 120-liter water flush at 1 l/min (per 10" equivalent)