GateKeeper Nonreactive Gas Purifiers

Cost-effective, environmentally friendly gas purification
 
  • Consistently delivers ultrapure gas
  • Designed for use with SF6, O2 , N2 O and O2 /inert gas mixtures. The purifiers remove CO2 and H2 O to sub-ppb (part-per-billion) levels; NMHCs to sub-ppt (part-per-trillion) levels.
  • Guards against bulk gas purifier breakthrough, impurity spikes from liquid storage tanks, cylinder changeouts and unexpected contaminants in the process
  • Does not release hydrocarbons that may contaminate the process
  • Uses ambient temperature purification technology – no power or heat required
  • Low pressure drop across purifiers
 
GateKeeper Nonreactive Gas Purifiers
Materials of construction:316L stainless steel, electropolished 10 Ra
Media:Specialty inorganic oxides
Gases purified:SF6, CO2, O2, N2O, O2 / inert gas mixture
Outlet purity:<1 ppb CO2, H2O; only H2O is removed from SF6 and CO2; <1 ppt nonmethane hydrocarbons
Outlet particle filtration:0.003 μm
Maximum differential pressure:1379 kPa (200 PSID)
Minimum operating pressure:101 kPa (14.7 PSIA)
Maximum flow rates:See datasheet.
Leak rating:1 × 10-9 atm cc/sec.
Maximum inlet challenge of contaminant to maintain product efficiency:10 ppm (part-per million)
Lifetime:One year at nominal flow rate with 1 ppm inlet challenge of moisture
Maximum operating temperature:65°C (149°F)