header top curve
Home   >   Products   >   Purification   >   Gas Purification   >   GateKeeper® Gas Purifiers   >   GateKeeper® Optics Gas Purifiers

Products

Select one or more of the following fields in order to begin your search.
  Search by Industry   Applications or process step   Keyword or Product Name      
   and/or   and/or      Search

Special Note: Some product links may direct you to our peripheral websites (devicecare.com, diskcare.com, entegrisfluidhandling.com, wafercare.com, entegris-services.com, or entegrisfuelcells.com)

GateKeeper Optics Gas Purifiers

Cost-effective, environmentally friendly gas purification
 
  • Consistently delivers ultrapure gas
  • Designed for use with CDA (clean dry air)
  • Guards against bulk gas purifier breakthrough, impurity spikes from liquid storage tanks, cylinder changeouts and unexpected contaminants in the process
  • Does not release hydrocarbons that may contaminate the process
  • Uses ambient temperature purification technology – no power or heat required
  • Low pressure drop across purifiers
 
GateKeeper Optics Gas Purifiers
Materials of construction:316L stainless steel, electropolished 10 Ra
Media:Inorganic
Gases purified:CDA
Outlet purity:<1 ppb H2S, H2O, CO2, amines, acid gases and alcohols; <100 ppt NOx, <10 ppt NH3; <1 ppt nonmethane hydrocarbons, siloxanes, SO2
Outlet particle filtration:0.003 μm
Model 200M: 20 μm
Maximum differential pressure:1379 kPa (200 PSID)
Minimum operating pressure:101 kPa (14.7 PSIA)
Maximum flow rates:See datasheet.
Leak rating:1 × 10-9 atm cc/sec.
Model 200M: 4 × 10-9 atm cc/sec.
Maximum inlet challenge of contaminant to maintain product efficiency:10 ppm (part-per million)
Lifetime:One year at nominal flow rate with 1 ppm inlet challenge of moisture
Maximum operating temperature:65°C (149°F)