IntelliGen® MV Dispense Systems
To discuss your specific needs, contact your local Entegris representative.
Don't have an Entegris representative?
Contact UsThank you for requesting a quote. Someone from Entegris will contact you shortly.
Your quote number is {0}.
- Medium-viscosity (100-300 cP) point-of-use photochemical dispense
Specifications
The dimensions shown are for all available IntelliGen® MV dispense system fitting configurations.
Comparing Dispense Confirmation and Air Detection Performance
This graph compares dispense confirmation and air detection performance at a 300 cP chemical level when a 0.3 mL air bubble is introduced into the process.
Dispense Repeatability
This graph shows dispense repeatabililty trending over a span of 200 dispense cycles.
Dispense performance | Volume | 0.01 - 10.0 mL in 0.001 mL increments |
Rate | 0.1 – 3.0 mL/sec in 0.001 mL/sec increments | |
Repeatability | <0.02 mL 3 sigma | |
Viscosity range* | 100 – 300 cP | |
Maximum dispense design pressure** | 0.40 MPa (60 psi) | |
Recharge performance | Fill rate, filtration rate, vent rate, purge rate | 0.1 – 3.0 mL/sec in 0.001 mL/sec increments |
Vent frequency | Auto-venting or 1 – 10,000 dispense cycles | |
Mechanical | Wetted surfaces | Modified PTFE, PTFE, Kalrez® |
Connection type | Insert style, Super Pillar or Flowell 60 series | |
Filter | Impact 8G, Impact 2 V2 (OF style) | |
Inlet, outlet and vent tubing | OD 0.25” (6.35 mm) or 0.24” (6.0 mm) ID 0.15628” (3.97 mm) or 0.16” (4.0 mm) |
|
Inlet gas type | Regulated N2 or CDA | |
Operating conditions | Minimium operating pneumatic pressure: 448 kPa (65 psi) Maximum operating pneumatic pressure: 469 kPa (68 psi) Pneumatic leak pressure: 600 kPa (87 psi) |
|
Vacuum | - 68 kPa (20 in -Hg min.) | |
Dimensions | Height | 9.55" (242.6 mm) |
Width | 2.39" (60.7 mm) | |
Depth | 9.25" (235.0 mm) | |
Weight | Approx. 5 kg (11 lb) | |
Electrical | Current rating | 1.25A |
Input voltage (system) | 24 VDC ±10% | |
Serial communication | Specifications are dependent on interface module use | |
Parallel communication | Triggers and acknowledgments | |
Certifications | See provided documentation | |
Environment | Indoor use only | |
Altitude below 2000 m (2187.22 yd) | ||
Ambient temperature 5°C – 40°C (41°F –104°F) | ||
Maximum relative humidity 80% for temperatures up to 31°C (88°F) decreasing linearly to 50% relative humidity at 40°C (104°F) | ||
Mains supply fluctuations from 22 – 26 VDC | ||
Transient overvoltages of overvoltage category II | ||
Pollution degree 2 | ||
*Depends on tool configuration. Contact applications support for detailed window of operation **Maximum pressure is a limit on the Window of Operation. Actual volumes and rates may be restricted to comply with the pressure limits for a given viscosity, tubing diameter, tubing length and tubing height. |
Successfully Opted for software Updates
Part Number | Style | Fitting Type | Cable Length | Connector |
---|---|---|---|---|
IGMVPHAW2 | Horizontal | 6 mm Flowell™ 60 series | 3.0 m | D-Sub 15 pin |
IGMVPVAP1 | Vertical | 1/4" Super Type Pillar® | 3.0 m | D-Sub 15 pin |
IGMVPVAP2 | Vertical | 6 mm Super Type Pillar® | 1.2 m | D-Sub 15 pin |
IGMVPVAP3 | Vertical | 3/8" Super Type Pillar® | 3.0 m | D-Sub 15 pin |
IGMVPVBP1 | Vertical | 1/4" Super Type Pillar® | 1.25 m | D-Sub 15 pin |
IGMVPVCP1 | Vertical | 1/4" Super Type Pillar® | 0.80 m | D-Sub 15 pin |
IGMVPVDP1 | Vertical | 1/4" Super Type Pillar® | 1.2 m | D-Sub 15 pin |