IntelliGen® ULV Dispense Systems
To discuss your specific needs, contact your local Entegris representative.
Don't have an Entegris representative?
Contact UsThank you for requesting a quote. Someone from Entegris will contact you shortly.
Your quote number is {0}.
The advanced two-stage system builds on the proven performance of dispense technology combined with Connectology filter design to provide dispense accuracy and repeatability in:
- Ultra-low viscosity (1-100 cP) point-of-use photochemical dispense
Specifications
Dispense performance: | Volume | 0.01 – 10.0 mL in 0.001 mL increments | |
Rate | 0.1 – 3.0 mL/sec in 0.001 mL/sec increments | ||
Repeatability | ≤ 0.02 mL 3 sigma | ||
Viscosity range* | 1 – 100 cP | ||
Maximum dispense design pressure** | 0.21 MPa (30 psid) | ||
Recharge performance: | Fill rate, filtration rate, vent rate, purge rate | 0.1 – 3.0 mL/sec in 0.001 mL/sec increments | |
Vent frequency | Auto-venting or 1–10,000 dispense cycles | ||
Mechanical: | Wetted surfaces | Modified PTFE, PTFE, Kalrez® | |
Connection type | Insert style, Super Type Pillar® or Flowell™ 60 series | ||
Filter | Impact® 8G or Impact 2 V2 (OF style) | ||
Inlet, outlet and vent tubing | OD | 6.35 mm (0.25”) or 6.0 mm (0.24”) | |
ID | 3.97 mm (0.15628”) or 4.0 mm (0.16”) | ||
Gas | Inlet gas type | Regulated N2 | |
Operating conditions | Minimium operating pneumatic pressure: 0.26 MPa (38 psi) Maximum operating pneumatic pressure: 0.28 MPa (40 psi) Pneumatic leak pressure: 0.30 MPa (43 psi) | ||
Vacuum | -68 kPa (20 in -Hg min.) | ||
Dimensions: | Height | 200.1 mm (7.878”) | |
Width | 60.7 mm (2.39") | ||
Depth | 216.5 mm (8.52") | ||
Weight: | Approximately 5 kg (11 lb) | ||
Electrical: | Current rating | 1.25A maximum | |
Input voltage (system) | 24 VDC ±10% | ||
Serial communication | Specifications are dependent on interface module use | ||
Parallel communication | Triggers and acknowledgments | ||
Certifications: | See provided documentation | ||
Environment: | Indoor use only | ||
Altitude below 2000 m (2187.22 yd) | |||
Ambient temperature 5°C – 40°C (41°F –104°F) | |||
Maximum relative humidity 80% for temperatures up to 31°C (88°F) decreasing linearly to 50% relative humidity at 40°C (104°F) | |||
Mains supply fluctuations from 22 – 26 VDC | |||
Transient overvoltages of overvoltage category II | |||
Pollution degree 2 |
* Depends on tool configuration. Contact applications support for detailed window of operation.
** Maximum pressure is a limit on the Window of Operation. Actual volumes and rates may be restricted to comply with the pressure limits for a given viscosity, tubing diameter, tubing length and tubing height.
Successfully Opted for software Updates
Part Number | Fitting Type | Cable Length | Connector | Post Cleaning (OK73 thinner flushing) | Options |
---|---|---|---|---|---|
IGULVPVAP1 | 1/4" Super Type Pillar® | 3.0 m | D-Sub 15 pin | N/A | N/A |
IGULVPVAP1F1 | 1/4" Super Type Pillar® | 3.0 m | D-Sub 15 pin | 1000 times flushing | N/A |
IGULVPVAP1F6 | 1/4" Super Type Pillar® | 3.0 m | D-Sub 15 pin | 6000 times flushing | N/A |
IGULVPVAW1 | 1/4" Insert style Flowell™ 60 series | 3.0 m | D-Sub 15 pin | N/A | N/A |
IGULVPVAW4 | 1/4" Flowell™ 60 series (in, out), 4 mm Flowell™ 60 series (vent) | 3.0 m | D-Sub 15 pin | N/A | N/A |
IGULVPVAW4F1 | 1/4" Flowell™ 60 series (in, out), 4 mm Flowell™ 60 series (vent) | 3.0 m | D-Sub 15 pin | 1000 times flushing | N/A |
IGULVPVAW4F6 | 1/4" Flowell™ 60 series (in, out), 4 mm Flowell™ 60 series (vent) | 3.0 m | D-Sub 15 pin | 6000 times flushing | N/A |
IGULVPVAW4M | 1/4" Flowell™ 60 series (in, out), 4 mm Flowell™ 60 series (vent) | 3.0 m | D-Sub 15 pin | N/A | On manifold (OM) filter connection |
IGULVPVBP1 | 1/4" Super Type Pillar® | 1.25 m | PA-Con 15 pin | N/A | N/A |
IGULVPVBP1F1 | 1/4" Super Type Pillar® | 1.25 m | PA-Con 15 pin | 1000 times flushing | N/A |
IGULVPVCP1 | 1/4" Super Type Pillar® | 0.80 m | D-Sub 15 pin | N/A | N/A |
IGULVPVCP1F1 | 1/4" Super Type Pillar® | 0.80 m | D-Sub 15 pin | 1000 times flushing | N/A |
IGULVPVGP1 | 1/4" Super Type Pillar® | 0.1 m | D-Sub 15 pin, 3 lines | N/A | N/A |
IGULVPVGP1TD | 1/4" Super Type Pillar® | 0.1 m | D-Sub 15 pin, 3 lines | N/A | Thermo device type |
IGULVPVHP2 | 6 mm Super Type Pillar® | 1.25 m | D-Sub 15 pin | N/A | N/A |
IGULVPVJP2 | 6 mm Super Type Pillar® | 10.0 m | D-Sub 15 pin | N/A | N/A |