GPS8 Nitrogen Gas Purifiers
Contact your Entegris account manager or
- Semiconductor
- Data storage
- Flat panel display
- LED
- Solar
Specifications
Model | H (cm) | W (cm) | D (cm) | Weight (kg) | |
PS8-MGS10 - PS8-MGS40 | 138 | 80 | 40 | <110 | |
PS8-MGS50 - PS8-MGS60 | 168 | 87 | 61 | <180 | |
PS8-MGS90 - PS8-MGS120 | 165 | 100 | 70 | <300 | |
GPS8-MGT200 - GPS8-MGT300 | 216 | 170 | 127 | <1,500 | |
GPS8-MGT400 - GPS8-MGT1400 | 216 | 229 | 170 | <2,300 | |
GPS8-MGT1500 - GPS8-MGT3000 | 241 | 279 | 193 | <5,600 | |
GPS8-MGT3500 - GPS8-MGT6000 | 272 | 325 | 264 | <7,100 | |
GPS8-MGT6600 - GPS8-MGT12500 | 272 | 376 | 270 | <8,500 | |
GPS8-MGT13000-GPS8-MGT20000 | 272 | 457 | 270 | <9,500 | |
Outdoor Enclosure Options (OPAL) Factory Regenerable Bulk Gas Purifiers (PS14) |
For outdoor installation, see our outdoor enclosure options Ambient temperature weld gas or temporary purification |
||||
Gas purified | N2 | ||||
Impurities removed to <1 ppb | H2O, O2, CO, CO2, H2 | ||||
ANALYTICAL SPECIFICATIONS |
|||||
IMPURITY | STANDARD INLET PURITY1 | STANDARD OUTLET PURITY 1 , 2 | |||
O2 | <2.0 ppm | <0.1 ppb | |||
CO | <1.0 ppm | <0.1 ppb | |||
CO2 | <0.5 ppm | <0.1 ppb | |||
H2 | <2.0 ppm | <0.15 ppb | |||
H2O | <5.0 ppm | <0.1 ppb | |||
TOC (>C5 as C7H8) | -- | <1.0 ppt3 | |||
Acids (as SO2) | -- | <1.0 ppt3 | |||
Bases (as NH3) | -- | <5.0 ppt3 | |||
Refractory Compounds (as HMDSO) | -- | <1.0 ppt3 | |||
1 Consult factory for non-standard inlet or outlet purity requirements. 2 Tested to <1ppbv at the factory. Gas purity levels indicated will be achieved after the purifier has performed two regenerations per adsorber bed after on-site commissioning. 3 Not tested at the factory. |
|||||
Flow rates | Nm3/hr | slpm | |||
PS8-MGS10 - PS8-MGS40 | 10 - 40 | 167 - 667 | |||
PS8-MGS50 - PS8-MGS60 | 50 - 60 | 833 - 1000 | |||
PS8-MGS90 - PS8-MGS120 | 90 - 120 | 1500 - 2000 | |||
GPS8-MGT200 - GPS8-MGT300 | 200 - 300 | 3333 - 5000 | |||
GPS8-MGT400 - GPS8-MGT1400 | 400 - 1400 | 6667 - 23,324 | |||
GPS8-MGT1500 - GPS8-MGT3000 | 1500 - 3000 | 24,990 - 49,980 | |||
GPS8-MGT3500 - GPS8-MGT6000 | 3500 - 6000 | 58,310 - 99,960 | |||
GPS8-MGT6600 - GPS8-MGT12500 | 6600 - 12,500 | 109,956 - 208,250 | |||
GPS8-MGT13000 - GPS8-MGT20000 | 13,000 - 20,000 | 216,580 - 333,200 | |||
Maximum pressure drop | <0.7 bar (70 kPa) | ||||
Note: Purifiers are gas specific and should only be used for the gas indicated. | |||||
Standard Features |