PrimeLock® Straight Adapter, JIS Flange
To discuss your specific needs, contact your local Entegris representative.
Don't have an Entegris representative?
Contact UsThank you for requesting a quote. Someone from Entegris will contact you shortly.
Your quote number is {0}.
We recommend our PrimeLock Connection Verification Gauge to easily and quickly verify your initial PrimeLock connection is properly tightened and secure. Reference the link at the bottom of this page under Related Products for details.
Note: Part number PS-4K12JF-3 uses a special PrimeLock Connection Verification Gauge, PGAUGE-4-NF. Contact Entegris for ordering information.
- High-purity, corrosive chemical handling
- Semiconductor applications
- Photolithography
- Bulk chemical delivery
- CMP
- Wet etch and clean
- High-temperature cleaning processes
- Solar, LED, flat panel display
- Excellent performance with low surface tension chemistries
Specifications
Part Number | Leg 1 | Leg 2 | Orifice | Dimensions | |||||
A | B | C | D | E | Hex | ||||
PS-4K12JF-3 | 1/4" PrimeLock | 20A (3/4") JIS Flange | 0.16" (4.1 mm) | 2.02" (51.3 mm) | 2.05" (52.1 mm) | 0.79" (20.1 mm) | 1.30" (33.0 mm) | 0.24" (6.1 mm) | 1" |
PS-8K8JFL-3 | 1/2" PrimeLock | 15A (1/2") JIS Flange | 0.37" (9.4 mm) | 2.44" (62.0 mm) | 1.91" (48.5 mm) | 0.59" (15.0 mm) | 1.02" (25.9 mm) | 0.24" (6.1 mm) | 1" |
PS-8K12JF-3 | 1/2" PrimeLock | 20A (3/4") JIS Flange | 0.37" (9.4 mm) | 2.44" (62.0 mm) | 2.05" (52.1 mm) | 0.79" (20.1 mm) | 1.30" (33.0 mm) | 0.24" (6.1 mm) | 1" |
PS-12K12JFL-3 | 3/4" PrimeLock | 20A (3/4") JIS Flange | 0.62" (15.7 mm) | 2.85" (72.4 mm) | 2.05" (52.1 mm) | 0.79" (20.1 mm) | 1.40" (35.6 mm) | 0.24" (6.1 mm) | 1 3/8" |
PS-16K16JFL-3 | 1" PrimeLock | 25A (1") JIS Flange | 0.87" (22.1 mm) | 3.29" (83.6 mm) | 2.52" (64.0 mm) | 0.98" (24.9 mm) | 1.77" (45 mm) | 0.24" (6.1 mm) | 1 5/8" |
PS-16K24JF-3 | 1" PrimeLock | 40A (1 1/2") JIS Flange | 0.87" (22.1 mm) | 3.64" (92.5 mm) | 3.29" (83.6 mm) | 1.56" (39.6 mm) | 2.34" (59.4 mm) | 0.35" (8.9 mm) | 1 5/8" |
PS-24K24JFL-3 | 1 1/2" PrimeLock | 40A (1 1/2") JIS Flange | 1.33" (33.8 mm) | 4.42" (112.3 mm) | 3.29" (83.6 mm) | 1.56" (39.6 mm) | 2.52" (64.0 mm) | 0.35" (8.9 mm) | N/A |
PS-M40K24JF-3 | 40 mm PrimeLock | 40A (1 1/2") JIS Flange | 1.33" (33.8 mm) | 4.38" (111.3 mm) | 3.37" (85.6 mm) | 1.56" (39.6 mm) | 3.00" (76.2 mm) | 0.35" (8.9 mm) | N/A |
Note: 1 1/4" PrimeLock "SpaceSaver" connections are rated to 586 kPa (85 psig) @ 100°C (212°F).
Fittings Reliability Test Results
Test Type | Test Conditions | Acceptance Criteria | Results |
Burst pressure | Media pressure increased until leak occurs | No external leakage prior to tube rupturing | PASS No external leakage |
Cyclic pressure leak test | 1/4"-1 1/4": 1241 kPa (180 psig) water @ 23°C (73°F) | No external leakage after 1 million cycles @ 1.5 × rated pressure | PASS No external leakage |
1 1/2" and 40 mm: 1034 kPa (150 psig) water @ 23°C (73°F) | |||
1/4"-1 1/4": 414 kPa (60 psig) hydraulic oil @ 200°C (392°F) | No external leakage after 1 million cycles @ 1.5 × rated pressure | PASS No external leakage |
|
1 1/2" and 40 mm: 414 kPa (60 psig) hydraulic oil @ 150°C (302°F) | |||
High pressure leak test | Submerge fitting Apply nitrogen pressure equaling 80% of the tube burst pressure |
No external leakage allowed | PASS No external leakage |
Tube pull out test | Apply tensile load to tube/fitting until tube separates from fitting | 1/4" (178 N) 40 lbf 3/8" (400 N) 90 lbf 1/2" (534 N) 120 lbf 3/4" (890 N) 200 lbf 1" (1112 N) 250 lbf 1 1/4" (1557 N) 350 lbf 1 1/2" and 40 mm (1779 N) 400 lbf |
PASS |
Chemical testing | Sulfuric acid Fluorosurfactant Copper sulfate 25% TMAH |
No external leakage after 2 million cycles | PASS PASS PASS PASS |
1/4" - 1 1/4" Sizes | 1 1/2" and 40 mm Sizes | ||
Materials | Body, insert, nut | PFA | PFA |
Connection verification ring | ETFE | ETFE | |
Operating conditions* | Media pressure | 827 kPa (120 psig) @ 21°C (70°F) | 689 kPa (100 psig) @ 21°C (70°F) |
276 kPa (40 psig) @ 200°C (392°F) | 276 kPa (40 psig) @ 150°C (302°F) | ||
Temperature range (fluid) | -18° to 200°C (0°– 392°F) | -18° to 150°C (0°– 302°F) | |
Compliant | RoHS | RoHS | |
*1 1/4" PrimeLock "SpaceSaver" connections are rated to 586 kPa (85 psig) @ 100°C (212°F). |
Recommended Torque
JIS Flange Size | Bolt Diameter | Recommended Bolt Torque |
15A (1/2") | 12 mm | 170 in•lbs 19.2 (N•m) |
20A (3/4") | 12 mm | 170 in•lbs 19.2 (N•m) |
25A (1") | 16 mm | 195 in•lbs 22.0 (N•m) |
40A (1 1/2") | 16 mm | 195 in•lbs 22.0 (N•m) |
Applicable PFA Tube Dimensions
OD | OD Tolerance | Wall Thickness | Wall Thickness Tolerance |
1/4" (6.35 mm) | ±0.004" (±0.10 mm) | 0.047" (±1.19 mm) | ±0.004" (±0.10 mm) |
3/8" (9.52 mm) | ±0.004" (±0.10 mm) | 0.062" (±1.57 mm) | ±0.005" (±0.13 mm) |
1/2" (12.70 mm) | ±0.005" (±0.13 mm) | 0.062" (±1.57 mm) | ±0.005" (±0.13 mm) |
3/4" (19.05 mm) | ±0.005" (±0.13 mm) | 0.062" (±1.57 mm) | ±0.005" (±0.13 mm) |
1" (25.40 mm) | ±0.005" (±0.13 mm) | 0.062" (±1.57 mm) | ±0.005" (±0.13 mm) |
1 1/4" (31.75 mm) | ±0.007" (±0.18 mm) | 0.075" (±1.90 mm) | ±0.007" (±0.18 mm) |
1 1/2" (38.10 mm) and 40 mm | ±0.007" (±0.18 mm) | 0.086" (±2.18 mm) | ±0.007" (±0.18 mm) |
Successfully Opted for software Updates
1 1/2" PrimeLock® Fitting Wrench Tightening Instructions
PrimeLock® Insert Installation using a Power Drill for 1 1/4" , 1 1/2" or 40 mm tubing
PrimeLock® Insert Installation Instructions
PrimeLock® Minimum Tube Union Insert Installation Instructions
PrimeLock Fittings
PrimeLock® Fitting Technology and Installation Overview
PrimeLock® Fitting Introduction
Part Number | Leg 1 | Leg 2 |
---|---|---|
PS-12K12JFL-3 | 3/4" PrimeLock® | 20A (3/4") JIS Flange |
PS-16K16JFL-3 | 1" PrimeLock® | 25A (1") JIS Flange |
PS-24K24JFL-3 | 1 1/2" PrimeLock® | 40A (1 1/2") JIS Flange |
PS-4K12JF-3 | 1/4" PrimeLock® | 20A (3/4") JIS Flange |
PS-8K8JFL-3 | 1/2" PrimeLock® | 15A (1/2") JIS Flange |
We recommend our PrimeLock Connection Verification Gauge to easily and quickly verify your initial PrimeLock connection is properly tightened and secure. Reference the link at the bottom of this page under Related Products for details.
Note: Part number PS-4K12JF-3 uses a special PrimeLock Connection Verification Gauge, PGAUGE-4-NF. Contact Entegris for ordering information.